Sew ST-850
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
SPECIFICATIONS
Voltage
90V-600V AC
Frequency response
50 / 60 Hz
Operating temperature & humidity
0°C ~ 40°C at 80% Max. relative humidity
Storage temperature & humidity
-10°C ~ 50°C at 90% Max. relative humidity
Cord
1.1m each of red(R), white(S) and black(T) cord
Dimensions
134(L) × 85(W) × 45(D)mm
Weight
Approx. 510g
Safety standard
IEC 1010 CAT II 600V
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 4183 CP
|
FEATURES
● Safely operates at low voltage ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated.
SPECIFICATIONS
Voltage ranges
0~16kV / 0~32kV
Accuracy
±8% (exclusive of tap capacitance variations)
Tap capacitance setting
0.4 to 3.0 pF continuous per channel
Frequency
50 or 60 Hz
Dimensions
250(L) × 190(W) × 110(D)mm
Weight (battery included)
Approx. 1420g
Power source
1.5V (AA) × 4
Safety standard
EN 61326-1
|
Cable Phasing Meter
|
|
|
|
Sew 1010 CL
|
FEATURES
● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.● TAUT BAND movement.
SPECIFICATIONS
AC A
10 / 30 / 100 / 300 / 1000A ±3% of F.S.(50/60Hz)
AC V
150 / 300 / 750V ±3% of F.S.
DC V
──
Ω
2kΩ ±3% of Scale length
Frequency response
50 / 60Hz for ACA 10A 50-400Hz for ACA 30 / 100 / 300 / 1000A
Dimensions
227(L) × 73(W) × 33(D)mm
Conductor size
52mm Max.
Weight (battery Included)
Approx. 460g
|
Rotary Scale Clamp Meters
|
|
|
|
Sew ST-600
|
FEATURES
● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.
SPECIFICATIONS
AC A
6 / 30 / 60 / 300 / 600A ±3% of F.S.(50/60Hz)
AC V
150 / 300 / 600V ±3% of F.S.
DC V
──
Ω
2kΩ ±3% of Scale length
Frequency response
50 / 60Hz for ACA 6A 50-400Hz for ACA 30 / 60 / 300 / 600A
Dimensions
230(L) × 72(W) × 37(D)mm
Conductor size
38mm Max.
Weight (battery Included)
Approx. 420g
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
Rotary Scale Clamp Meters
|
|
|
|
Sew ST-375
|
FEATURES
● Designed for measuring AC current, AC voltage resistance and DC voltage .● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.
SPECIFICATIONS
AC A
6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz)
AC V
300 / 600V ±3% of F.S.
DC V
75V ±3% of F.S.
Ω
2kΩ ±3% of Scale length
Frequency response
50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A
Dimensions
230(L) × 72(W) × 37(D)mm
Conductor size
38mm Max.
Weight (battery Included)
Approx. 420g
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
Rotary Scale Clamp Meters
|
|
|
|
Sew ST-3620
|
FEATURES
● 3½ digit liquid crystal display with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges
SPECIFICATIONS
AC A
200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz)
AC V
200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)
Ω
200Ω ±(1.5%rdg+2dgt)
Buzzer
Resistance is less then 30Ω
Peak hold
ˇ
Conductor size
55mm Max.
Operating temperature
0ºC ~ 40ºC
Humidity
85%
Current consumption
Approx. 10mA
Dimensions
245(L) × 70(W) × 41.7(D)mm
Weight (battery Included)
Approx. 480g
Power source
9V(6F22) × 1
|
AC Clamp Meters
|
|
|
|
Sew ST-2600
|
FEATURES
● Full auto range for V.A and Ω functions. ● Data hold function freezes the reading in dimly lit or hard to reach places. ● Low battery indication. ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A ±(2.0%rdg+3dgt) : 50/60Hz
AC V
400 / 600V ±(1.2%rdg+3dgt) : 40-500Hz
Ω
4kΩ ±(1.5%rdg+3dgt)
Buzzer sounds
< 100Ω
Conductor size
27mm Max.
Low battery Indication
Dimensions
197(L) × 65(W) × 33(D)mm
Weight (battery Included)
Approx. 250g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
AC Clamp Meters
|
|
|
|
Sew 3904 CL
|
FEATURES
● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
400.0/2000A 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
DC V
400.0mV/4.000/40.00/400.0/1000V... |
AC/DC Clamp Meters
|
|