SEW-Taiwan
AC/DC Clamp Meters
| |
Name |
Description |
Category |
|
|
|
Sew 2660 CL
|
FEATURES
● 4000 counts.● Voltage measurement, current measurement, resistor measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
DC Voltage
Ranges
Resolution
Accuracy
400mV
0.1mV
±(1.0%rdg+3dgt)
4V
1mV
40V
10mV
400V
100mV
600V
1V
․Overload protection : 650V DC
AC Voltage
Ranges
Resolution
Accuracy
400mV
0.1mV
±(0.5%rdg+3dgt)
4V
1mV
±(1.5%rdg+3dgt)
40V
10mV
400V
... |
AC/DC Clamp Meters
|
|
|
|
Sew ST-3600
|
FEATURES
● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges
SPECIFICATIONS
AC A
200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz)
AC V
00 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)
DC A
200 / 1500A ±(2%rdg+4dgt)
DC V
20 / 200 / 1000V ±(1%rdg+2dgt)
Ω
200 / 1500Ω ±(1.5%rdg+2dgt)
Diode check
0-1500mV ±(1.5%rdg+2dgt)
Buzzer
──
Conductor size
55mm Max.
Operating temperature
0ºC ~ 40ºC
Humidity
85% R.H.
Current consumption
Approx. 10mA
Dimensions
245(L) × 70(W) × 41.7(D)mm
Weight (battery Included)
Approx. 480g
Power source
9V(6F22) × 1
|
AC/DC Clamp Meters
|
|
|
|
Sew ST-3602
|
FEATURES
● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges
SPECIFICATIONS
AC A
200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz)
AC V
200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)
DC A
200 / 1500A ±(2%rdg+4dgt)
DC V
200 / 1000V ±(1%rdg+2dgt)
Ω
200 / 1500Ω ±(1.5%rdg+2dgt)
Diode check
0-1500mV ±(1.5%rdg+2dgt)
Buzzer
Resistance is less than 100Ω
Conductor size
55mm Max.
Operating temperature
0ºC ~ 40ºC
Humidity
85% R.H.
Current consumption
Approx. 10mA
Dimensions
245(L) × 70(W) × 41.7(D)mm
Weight (battery Included)
Approx. 480g
Power source
9V(6F22) × 1
|
AC/DC Clamp Meters
|
|
|
|
Sew 3800 CL
|
FEATURES
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
───
LCD backlight display
───
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 420g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN... |
AC/DC Clamp Meters
|
|
|
|
Sew 3801 CL
|
FEATURES
● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
ˇ
LCD backlight display
ˇ
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 430g
Power source
9V(6F22) × 1
Safety... |
AC/DC Clamp Meters
|
|
|
|
Sew 3810 CL
|
FEATURES
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
───
LCD backlight display
───
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 420g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN... |
AC/DC Clamp Meters
|
|
|
|
Sew 3900 CL
|
FEATURES
● 4000- count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt) 40~500Hz
DC A
400.0/2000A... |
AC/DC Clamp Meters
|
|
|
|
Sew 3902 CL
|
FEATURES
● 2000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
200.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
200.0/2000A... |
AC/DC Clamp Meters
|
|