Sew ST-600
|
FEATURES
● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.
SPECIFICATIONS
AC A
6 / 30 / 60 / 300 / 600A ±3% of F.S.(50/60Hz)
AC V
150 / 300 / 600V ±3% of F.S.
DC V
──
Ω
2kΩ ±3% of Scale length
Frequency response
50 / 60Hz for ACA 6A 50-400Hz for ACA 30 / 60 / 300 / 600A
Dimensions
230(L) × 72(W) × 37(D)mm
Conductor size
38mm Max.
Weight (battery Included)
Approx. 420g
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
Rotary Scale Clamp Meters
|
|
|
|
Sew ST-375
|
FEATURES
● Designed for measuring AC current, AC voltage resistance and DC voltage .● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.
SPECIFICATIONS
AC A
6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz)
AC V
300 / 600V ±3% of F.S.
DC V
75V ±3% of F.S.
Ω
2kΩ ±3% of Scale length
Frequency response
50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A
Dimensions
230(L) × 72(W) × 37(D)mm
Conductor size
38mm Max.
Weight (battery Included)
Approx. 420g
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
Rotary Scale Clamp Meters
|
|
|
|
Sew ST-3620
|
FEATURES
● 3½ digit liquid crystal display with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges
SPECIFICATIONS
AC A
200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz)
AC V
200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)
Ω
200Ω ±(1.5%rdg+2dgt)
Buzzer
Resistance is less then 30Ω
Peak hold
ˇ
Conductor size
55mm Max.
Operating temperature
0ºC ~ 40ºC
Humidity
85%
Current consumption
Approx. 10mA
Dimensions
245(L) × 70(W) × 41.7(D)mm
Weight (battery Included)
Approx. 480g
Power source
9V(6F22) × 1
|
AC Clamp Meters
|
|
|
|
Sew ST-2600
|
FEATURES
● Full auto range for V.A and Ω functions. ● Data hold function freezes the reading in dimly lit or hard to reach places. ● Low battery indication. ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A ±(2.0%rdg+3dgt) : 50/60Hz
AC V
400 / 600V ±(1.2%rdg+3dgt) : 40-500Hz
Ω
4kΩ ±(1.5%rdg+3dgt)
Buzzer sounds
< 100Ω
Conductor size
27mm Max.
Low battery Indication
Dimensions
197(L) × 65(W) × 33(D)mm
Weight (battery Included)
Approx. 250g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT II 600V EN 61010-2-32
|
AC Clamp Meters
|
|
|
|
Sew 3904 CL
|
FEATURES
● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
400.0/2000A 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
DC V
400.0mV/4.000/40.00/400.0/1000V... |
AC/DC Clamp Meters
|
|
|
|
Sew 3902 CL
|
FEATURES
● 2000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
200.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
200.0/2000A... |
AC/DC Clamp Meters
|
|
|
|
Sew 3900 CL
|
FEATURES
● 4000- count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt) 40~500Hz
DC A
400.0/2000A... |
AC/DC Clamp Meters
|
|
|
|
Sew 3810 CL
|
FEATURES
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
───
LCD backlight display
───
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 420g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN... |
AC/DC Clamp Meters
|
|