Kyoritsu 5010 (for Current) / 5020 (for Current & Voltage)
|
3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
•
Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)
Large Capacity for storing 60,000 data points
60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
Lowpass Filter will filter out the harmonics(Cutoff Frequency = Approx. 160Hz)
LED flickers when the preset current / voltage value is exceeded
CALL: Confirmation of recorded data
•
The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
•
RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
|
Logger
|
|
|
|
Kyoritsu 8309
|
Floating voltage can be measured
*Floating voltage:phase to phase voltage not grounded
*KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.)
For use with following model
5020
|
Voltage Sensor
|
|
|
|
Kyoritsu 8129
|
Flexible for various test fields
•
Can measure AC current up to 3000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Measurable conductor size:max Φ150mm
•
Designed to meet the international safety standardIEC 61010-1 CAT.III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
|
Kyoritsu 8130
|
Can measure AC current up to 1000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
|
Kyoritsu 8123
|
Applicable model 5010/5020
Conductor size
Φ55
Rated current
AC 1000A
Output voltage
AC 500mV/1000A (AC 0.5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.5Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2
Dimensions
170(L) x 105(W) x 48(D) mm
Weight
Approx.360g
Accessories
9094 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
Kyoritsu 8122
|
Applicable model 5010/5020
Conductor size
Φ40
Rated current
AC 500A
Output voltage
AC 500mV/500A (AC 1mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.9Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2
Dimensions
128(L) x 81(W) x 36(D) mm
Weight
Approx.260g
Accessories
9095 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
Kyoritsu 8121
|
Applicable model 5010/5020
Conductor size
Φ24
Rated current
AC 100A
Output voltage
AC 500mV/100A (AC 5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 3540V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 9.5Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2
Dimensions
97(L) x 59(W) x 26(D) mm
Weight
Approx.150g
Accessories
9095 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
Kyoritsu 8148
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
|
Leakage & Load current clamp sensors
|
|