Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe For the Fluke 1750 Power Recorder
|
The Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3210PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamp DMM Accys
|
|
|
|
Fluke 3300 Clamp-on Current Transformer
|
Current range: 10-3000A
Accuracy: 2% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamp DMM Accys
|
|
|
|
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamp DMM Accys
|
|
|
|
Fluke 3583R Split-Core Current Transformers
|
Current range: 0.01 – 10A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3584R Split-Core Current Transformers
|
Current range: 0.1 – 40A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3585R Split-Core Current Transformers
|
Current range: 0.5 – 1-0A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer
|
Measuring Range selectable per software:0.01A to 1A0.1A to 10A
Peak current for sinusoidal currents:3.7A to 37A
Intrinsic error: 0.5%
Frequency Range: 40Hz to 10kHz
Operating Voltage: 300V CAT IV
Phase Error: 0.5°
Jaw Opening: <15mm diameter or 15x17mm bus bars
Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|