Sew 183 CB
|
FEATURES
Cable Tracer
● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset. (Amplifier probe)Phone Tester
● Continuity and resistance testing for voltage-free objects.● Check direct and alternating voltages.● Testing capacitors.● Testing diodes.● Power ON/OFF switch.● The indication of the LED lamp and the sound of the buzzer can occur at the same time.● The LED indication for Power ON status.
SPECIFICATIONS
Amplifier Probe
Frequency
1Hz~12kHz
Receiver distance
< 50cm
Sensitivity control
ˇ
Probe tip
Fixed
Power source
9V(6F22) × 1
Dimensions
230(L) × 56(W) × 27(D)mm
Weight
Approx. 125g (battery included)
Tone Generator
Wave form
Square Wave
Frequency
1kHz±15%
Over voltage protection
80V DC
Single tone
─
... |
Cable Tracer and Phone Tester
|
|
|
|
Sew 185 LCT
|
FEATURES
● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable.● The LAN cable tester can verify cable continuity, open, short circuit and miss-wired. ● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan functions.● Ground wire test. ● Lock status function.● Buzzer sound warning for wire status.● Display : LED indication for wire status.
SPECIFICATIONS
Display
LED
Operating temperature
0°C ~ 40°C
Dimensions
Master unit 132(L) × 55(W) × 39(D)mm Remote receiving unit 74(L) × 30(W) × 25(D)mm
Weight (battery included)
Master unit : 148 g Remote receiving unit : 33g
Power source
9V × 1
Safety standard
EN 61326-1
|
Lan Cable Tester
|
|
|
|
Sew 187 MCT
|
FEATURES
Lan Cable Tester
● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable etc.● The LAN cable tester can verify cable continuity, open, circuit and miss-wired. ● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan function.● Ground wire test.● Display : LED indication for wire status.
Digital Multimeter
● 4000 counts LCD.● Full automatic measurement. Voltage measurement. Resistor measurement.● Range change function.● Select function.● Data Hold function.● Continuity check.● Diode measurement.● Low battery indication.● Input impedance:10MΩ.
SPECIFICATIONS
AC Voltage
Range
Resolution
Accuracy
400mV
0.1mV
±(1.0%rdg+5dgt)
4V
1mV
40V
10mV
400V
100mV
750V
1V
DC Voltage
... |
Cable Tracer and Digital Multimeter
|
|
|
|
Sew 186 CB
|
FEATURES
Cable Tracer
● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset. (Amplifier probe) Digital Multimeter
● 4000 counts.● ACV, DCV.● Ohm, Diode, & Continuity testing.● Auto-range.● Data hold.● Low battery indication.● Select function.● Auto-off.
SPECIFICATIONS
AC Voltage
Range
Resolution
Accuracy
400mV
0.1mV
±(1.0%rdg+5dgt)
4V
1mV
40V
10mV
400V
100mV
750V
1V
DC Voltage
Range
Resolution
Accuracy
400mV
0.1mV
±(0.5%rdg+3dgt)
4V
1mV
40V
10mV
400V
100mV
1000V
1V
Resistance
Range
Resolution
Accuracy
... |
Cable Tracer and Digital Multimeter
|
|
|
|
Sew 895 PR
|
FEATURES
● Non-contact detector clips. No metal contact points to advocate greater safety.● Two functions in one unit : open phase and phase sequence detection.● Designed for checking a wider range of 3-phase power sources.● LED display lights with buzzer indicator. ● Brightness button feature for better visibility in dimly lit areas or sunlight.● Magnetic mounting feature.
SPECIFICATIONS
Measurement principle
Static induction
Input voltage
75~1000Vac
Frequency range
45-65Hz
Auto-off
5 min. after power on without detection
Low battery warning
Power LED flashes at 7V ± 0.2 or less
Operating temperature & humidity
0°C ~ 40°C Max. 80% R.H.
Storage temperature & humidity
-10°C ~ 50°C Max. 80% R.H.
Cable length
Approx. 800mm
Dimensions
128(L) × 72(W) × 44(D)mm
Weight (battery included)
Approx. 380g
Power source
9V (6LF22) × 1
Safety standard
EN 61010-1... |
Non-Contact Type Phase Sequence Indicators
|
|
|
|
Sew 890 PR
|
FEATURES
● The 890 PR is a Non-Contact phase detector with flashing LEDs and a beeping buzzer to show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and phase sequence detection.● Convenient brightness switch to make the indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz.
SPECIFICATIONS
Measurement principle
Static induction
Input voltage
75~1000Vac
Frequency range
45-65Hz
Auto-off
5 min. after power on without detection
Low battery warning
Power LED flashes at 4.6±0.1V or less
Operating temperature & humidity
0°C ~ 40°C Max. 80% R.H.
Storage temperature & humidity
-10°C ~ 50°C Max. 80% R.H.
Cable length
Approx. 800mm
Dimensions
118(L) × 69(W) × 38(D)mm
Weight (battery included)
Approx. 370g
... |
Non-Contact Type Phase Sequence Indicators
|
|
|
|
Sew 4156 PR
|
FEATURES
● The 4156 PR is used to identify the leads of a diconnected motor so that when the motor is in true phase sequence, it will run in the desired direction.
SPECIFICATIONS
Measuring ranges
0~200kΩ
Test leads
AL-34 length : 50cm
Dimensions
250(L) × 190(W) × 110(D)mm
Weight (battery included)
Approx. 1280g
Power source
1.5V (AA) × 2
Safety standard
EN 61010-1 EN 61326-1
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 888 PMR
|
FEATURES
● Indicates phase rotation. ● Indicates phase presence.● Indicates motor rotation/wiring.● Indicates battery status.● Phase rotation and motor rotation indication works from as low as 1Vac.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 100 Vac. ● Very low consumption.● Fused. ● Lightweight, robust and compact.● Works from 2 Hz to 400 Hz Sine.
SPECIFICATIONS
Phase Presence Nominal Voltage for Phase Presence Indication (The voltage required for the neon Lamps L1, L2, L3 to light up).
From To Freq
100Vac 500Vac 10-400Hz
Determination of Phase Rotation Field Direction
From To Freq
1Vac 500Vac 2-400Hz
Determination of Motor Connections (requires > 1/2 turn of the shaft)
From To Freq
1Vac 500Vac 2-400Hz
Maximum Current Consumption
18mA
Over Voltage CLASS III
500V
Over Load between all terminals
500V
Battery OK goes off when battery voltage
< 6.5 Vdc
Dimensions
... |
Phase Sequence Indicators (Contact Type)
|
|