OPT107+OPT108-Optical Dissolved Oxygen Sensor and DO Transmitter (DOS-20+SC-DO(E)) - Made in Japan
|
Combination use with MLSS Analyzer for biological treatment or MBR process
Robust Design -Inert ABS construction
Long Term Stability -No Influence by water flow rate
Robust Design
IP65 Water Jet Proof
Simple Key Operation
Mounting Attachment (DA-1)
Replacement Sensor Cap (DOS-CP)
Model
Detector DOS-20 / Transmitter (Outdoor Type) SC-DO
Measuring Parameter
Dissolved Oxygen (mg/L) Temperature (℃) Dissolved Oxygen Saturation Rate (%) Oxygen Partial Pressure (kPa)
Measuring Range/ Display Resolution
[Dissolved Oxygen] 0.00 ~20.00mg/L (0.01mg/L) [ Dissolved Oxygen Saturation Rate] 0.0 ~200.0% (0.1%) [Temperature]0.0 ~50.0℃ (0.1℃) [ Oxygen Partial Pressure]0.0 ~150.0kPa (0.1KPa)
Measurement Accuracy
±0.1mg/L (0~8mg/L) , ±0.2mg/L... |
Water
|
|
|
|
OPT109-SS Checker (TS-Mx) Suspended Solids Checker - Made in Japan
|
TS-Mx(E) (System model)
Wide range of 50,000 mg/L measurement as maximum
The wide range measurement can be possible to monitor MLSS concentration in the aeration basin.
Easy installation, Simple operation
For user-friendly, TS-Mx(E) is designed as a concept of easy installation and simple operation.
Built-in wiper cleaning system
The built-in wiper cleaning system certainly keeps lense clean.
Sapphire glass for scratch proof
The optical windows are made of hard-to scratch sapphire glass. It enables to scrub the window surface to matintain the Sensor.
TS-MxS-A (Analog output model)
4-20mA analog output
4-20mA analog output is provided from TS-MxS-A Sensor. It is possible to connect to the system such as PLC directly.
Wide range of 50,000 mg/L measurement as maximum
The wide range measurement can be possible to monitor MLSS concentration in the aeration basin.
Built-in wiper cleaning system
The built-in wiper cleaning system certainly... |
Water
|
|
|
|
OPT104-Suspended Solids Checker (TCS-1000)- Made in Japan
|
This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .
Analogue output (4-20mA) allows you to use this checker with various equipments.
Wiper for easy maintenance
Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month.
Compact size
Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit.
High durability
Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass.
Turbidity Checker TC-100/500/3000 SS Checker TCS-1000
The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.
As well as the turbidity/SS indication, this transmitter can indicate signal output response... |
Water
|
|
|
|
OPT103B-Transmitter SC-T4(E) - Made in Japan
|
The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.
As well as the turbidity/SS indication, this transmitter can indicate signal output response time, alarm level setting and so on. You can control the turbidity/SS utilizing its functions fully.
Power Supply
50/60Hz
Signal output
Alarm output
Degree of protection
Jet-proof type (IP65)
Transmitter forSuspended Solids Checker |
Water
|
|
|
|
OPT102-Portable Turbidity Monitoring Sensor ( TD-M500) - Made in Japan
|
Easy to measure turbidity.
You can easily measure the water turbidity anywhere with this portable sensor because it cannot be affected by external disturbance light.
Unnecessary to draw the water.
You just put the probe into the water to measure turbidity. You can avoid the hassle of drawing the water.
High durability
Controller Unit: Waterproof IP67. Anti-bacterial metrical is used. Sensor Unit: Durable SUS316L is used. Optical window is made of sapphire glass. It is equipped with a rubber to absorb the impact from wear and shock.
Model No.
TD-M500
Measuring Technique
Attenuated Light Method
Measuring Range
0.0-500FTU
Display Resolution
0.1FTU (0.0-99.9), 1FTU (100-500)
Calibration
Distilled Water or Air Calibration
Correction
Single or Double Point Correction
Power Requirements
9V Layer-built Alkaline Dry Battery (6LR61)
Battery Life
Approx. 8000 measurements
Water Temperature
0 to 40℃ (32 to 104°F)
Operating... |
Water
|
|
|
|
OPT101-Turbidity Checker (TC-100/500/3000) - Made in Japan
|
This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .
Analogue output (4-20mA) allows you to use this checker with various equipments.
Wiper for easy maintenance
Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month.
Compact size
Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit.
High durability
Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass.
Turbidity Checker TC-100/500/3000 SS Checker TCS-1000
The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.
As well as the turbidity/SS indication, this transmitter can indicate signal output response... |
Water
|
|
|
|
OPT100-Turbidity Checker(TSC-10) - Made in Japan
|
90 degree scattered light method
Turbidity Checker TSC-10(E) uses a method of 90 degree scattered light as the measuring principle of the world common standard.
Built-in wiper cleaning system
The built-in wiper cleaning system certainly keeps lenses clean.
Sapphire glass of the optical windows
The optical windows are made of hard-to-scratch sapphire glass. It enables to scrub the window surface to maintain the Turbidity Checker.
Compact design
The compact design makes it possible to install easily.
Turbidity Checker TSC-10(E) got the Pattern Approval Certificate of the measuring instruments of the People's Republic of China.
Model No.
TSC-10(E)
Measuring range
0.00-500.0 (NTU/FNU)
Power supply voltage
AC100-240V±10% 50/60Hz
Power consumption
Nomal:15VA or less, During cleaning:22VA max.
Display resoltion
0.01(0.00-19.99), 0.1(20.0-500.0)NTU/FNU
Output
Signal Output (analog 4-20mA, resistance load of 300 max.)
Self-checking Relay Output (non-voltage C-contact capacity 240VAC,... |
Water
|
|
|
|
Our Warranty
|
This section contains warranty information. |