AM-4214SD SD Hotwire airflow meter wth recording funtion
|
- Air velocity : 0.2 to 20.0 m/s
- Air temperature : 0 ℃ to 50 ℃
- Type K/J thermometer : -50.0 to 1300.0 ℃
|
Airflow meters
|
|
|
|
ATA0023-PAL-ES2 HIGH PRECISION DIGITAL SALT REFRACTOMETER 0.01% - SALINITY METER - MADE IN JAPAN
|
The new “Pocket” Salt-meter PAL-ES2 is suitable for measuring salt concentrations at restaurants and school cafeterias, as well as for the nourishment guidance in hospitals, and as teaching material at schools. The displayed unit is in g/100g. |
Water
|
|
|
|
AND1100 - ANDALYSE AND001 AND 1000 FLUORIMETER
|
Features:
Simple, one button push for on-site, detection and analysis of heavy metals in water
No specialized user training
Less than 2 minutes to test result
EPA Award winning Technology – Meets EPA testing requirements
Highly sensitive and selective
Test results can be downloaded via USB connection
Rechargeable through USB connection
Capability to re-sample quickly
Reduces time to begin remediation action
No harmful reagents, environmentally friendly
|
Water
|
|
|
|
ATA0003-PAL-ES3 Salt meter (salinity)
|
The new “Pocket” Salt-meter ATA0003-PAL-ES3 Salt meter (salinity) is suitable for inspections carried during the manufacturing process as well as for quality control at food factories. It is the best for the measuring the % concentration of salt in sauces, catsups, seasoning, and soups. The displayed unit is in g/100ml as in the Mohr’s method.
|
Water
|
|
|
|
AFLEX-3001/3002 Flexible AC Current Clamp
|
True RMS
3000A
Voltage Measurement (AFLEX 3002 only)
Fast Peak Function(30 μs)
MAX/MIN
Auto-Power-Off:30 minutes
Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm
AC Current (45~65Hz,True RMS)
Range
Range
Resolution
Accuracy of Readings
30 - 300 A
0.00 - 300A
0.1A
1% of range
300 - 999.9 A
100.0 - 999.9 A
0.1A
1% of range
1000 - 3000A
1000 - 3000 A
1A
1% of range
AC Voltage (AFLEX 3002 only, 45~65Hz, True RMS)
Range
Resolution
Accuracy of Readings
3 V - 600 V
0.1V
± 0.5% ± 5dgts
General Specification
Connector Diameter
23mm
Cable Diameter
14mm
Cable Length from Probe to Box
170mm
Conductor Size
170mm (approx.)
Battery Type
1.5V SUM-3*2
Power Consumption
10mA (approx.)
Auto - Power - Off
30 minutes
LCD update rate
2... |
Clamp meters
|
|
|
|
ATA0115-JAPAN DOM-244V2 FRYING/ COOKING OIL MONITOR (TEMP/TOTAL POLAR MOLECULES TPM/ACID VALUE)-From Japan
|
Overview
Introducing a frying oil monitor that can be used to periodically check and monitor the quality of oil.This instrument is capable of measuring both TPM (Total Polar Materials), a standard used in Europe as an indicator of the overall quality of frying oil, as well as AV (Acid Value), which indicates changes in cooking oil properties.
|
Cooking oil tester
|
|
|
|
ALM13** ADHT Ex Ex-Proof Dewpoint Transmitter
|
Model ADHT Ex - Dewpoint Transmitter
3 Wire, 24V, 4-20mA Dewpoint Transmitter
Intrinsically safe - ATEX II 1G / Ex ia IIC T6 Ga
Various Ranges: Overall Range -110ºC to +20ºC dewpoint
Accuracy ±2ºC Dewpoint
Weatherproof Rating IP65
Open/Short Circuit Detection
Built-in temperature compensation
Supplied with Calibration Certificate Traceable to National & International Humidity Standards
The Alpha Moisture Systems Model ADHT-Ex is a 3 wire, 24V powered 4-20mA dewpoint transmitter. The unit is fully self contained in a robust casing with weatherproof protection to IP65, making it ideal for use in heavy industrial environments.
Designed with the operator in mind, Model ADHT-Ex is extremely easy to use and the digitaldewSMARTtechnology ensures accurate and reliable readings with little or no maintainance.
Model ADHT is certified intrinsically safe to EEx ia IIC T6 for use in hazardous areas using an MTL 2441B signal isolator for 110V / 240V AC operation or MTL 5042 for 24V DC operation.
Various ranges are available covering an overall range from -110ºC to +20ºC dewpoint. The Model ADHT-Ex derives its power directly from the signal isolator and it is... |
Dew point meters
|
|
|
|
ALM12** AMT-EX - Dewpoint Transmitter
|
AMT-Ex Intrinsically Safe 4-20mA Transmitter
3 Wire Intrinsically Safe Dewpoint Transmitter
Ex II 1GD Ex ia IIC T4 Ex iaD 20 T135°C (-20°C ≤ Ta ≤ +60°C)
Overall Range: -120°C to +20°C Dewpoint
Accuracy ± 2°C Dewpoint
AUTOMATIC CALIBRATION
Can be configured for Linear 4-20mA signal in: °C & °F Dewpoint, ppm(v), g/m3, lb/MMSCF
Temperature Compensation
Failure Diagnostics
Long Term Stability
Fast Response
IP66 / NEMA4X Protection
Model AMT-Ex Dewpoint Hygrometeris a three wire 4-20mA transmitter, used for continuous measurement of humidity in a process gas or compressed air, which will output a linear 4-20mA signal corresponding to the dewpoint temperature. The Model AMT-Ex transmitter can also be factory configured to output a 4-20mA linear signal for any other moisture unit e.g. ppm(v), ppm(w), g/m3, lb/MMSCF etc.
The long lasting sensing element offers excellent sensitivity, repeatability and response speed. Each unit is supplied with a Certificate of Calibration, traceable to International Humidity Standards, validating accuracy to ±2ºC dewpoint.
Model AMT-Ex is ATEX certified and provides an Intrinsically Safe Dewpoint Transmitter for... |
Dew point meters
|
|