Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name Description Category
Testo 425 (0560 4251) Compact Thermal Anemometer Flow, volume flow (cfm) and temperature measurements Multi-point and timed mean calculations Max-Min values make comparisons fast and easy "Hold" button freezes readings Clear backlit display Auto Off Anemometers
Testo 425-KIT (400563 4251) Thermal Anemometer Kit, Temperature, Flow and Volume Flow Temperature, flow and volume flow measurement Multi-point and timed mean calculation Max/min values Hold button to freeze readings Display light Auto Off function Includes a soft carrying case TopSafe case protects against dirt and impact (optional) Anemometers
Testo 445 (0560 4450) VAC Testing Anemometer Automatic mean calculation and volume flow measurement Automatic allocation of duct cross-section to location (max. 99 locations) Internal data logger (3,000 readings) Simultaneous measurement of up to 6 parameters Anemometers
Testo 6445-1 (0699 6445 1) Compressed Air Flowmeter Measuring range: 0 to 80 Nm/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Minimum flow required: 1 m/sec Ambient temperature: -10 to +60° C Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA) Anemometers
Testo 6445-2 (0699 6445 2) Compressed Air Flowmeter Measuring range: 0 to 150 m/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Measuring range: -50 to 400 ° C Minimum flow required: 2 m/sec Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA) Anemometers
Testo 315-2 (0632 0317) CO Tester Reliable warning of CO poisoning DVGW approval Adjustment of different alarm limits Printout with date/time and recommended value (alarm limit) With calibration protocol TopSafe, protection case for tough applications Quick and practical documentation of data on location, printout with date/time and recommended value (alarm limit) CO Meters
Testo 317-3 (0632 3173) CO Monitor for carbon monoxide detection 3 year warranty on CO cell Visual and audible alarm No zeroing required, just turn it onto measure Adjustable alarm threshold Self-test mode verifies CO sensor function anytime, anywhere without the need for test gas CO Meters
Testo 310 Combustion Analyzers The Testo 310 can stand up to the toughest job site Five-line backlit display with two-line readout and easy-to-navigate menu 30 second start-up time Work all day with a 10-hour rechargable battery Quick swapable replacement filters Powerful magnets in the 310 allows for hands-free operation Easy emptying of the integrated condensate trap Wireless printer option with integrated magnets Combustion Analyzers