Sew 1151 IN-M
|
FEATURES
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ration (DAR).● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
250V / 500V / 1000V
Measuring ranges
0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
PI Function
ˇ
DAR Function
ˇ
|
Insulation & Multifunction Testers (OLED Display)
|
|
|
|
Sew 1152 MF-M
|
FEATURES
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ration (DAR).● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
250V / 500V / 1000V
Measuring ranges
0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
PI Function
ˇ
DAR Function
ˇ
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
ˇ
|
Insulation & Multifunction Testers (OLED Display)
|
|
|
|
Sew 1154 TMF-M
|
FEATURES
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ration (DAR).● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
50V / 100V / 125V / 250V / 500V /1000V
Measuring ranges
0.1M~400MΩ / 0.1M~800MΩ / 0.1M~1GΩ / 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
ˇ
|
Insulation & Multifunction Testers (OLED Display)
|
|
|
|
Sew 1155 TMF-M
|
FEATURES
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ration (DAR).● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
50V / 100V / 125V / 250V / 500V /1000V
Measuring ranges
0.1M~400MΩ / 0.1M~800MΩ / 0.1M~1GΩ / 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
PI Function
ˇ
DAR Function
ˇ
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
... |
Insulation & Multifunction Testers (OLED Display)
|
|
|
|
Sew TEL-1-1 110V
|
FEATURES
● The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.
SPECIFICATIONS
Nominal Voltage System
110V-220V-230V-240Vac available - User Selectable at purchase.
System Voltage Frequency
50-60Hz
Wiring Check Accuracy
Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect.
Earth / Ground Current Simulator Accuracy
Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum.
Overall Rating
Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST.
Resistance Rating
Current Injection System uses Resistors which are Not Continuously Rated.
Case Material
ABS
Safety Standard
EN 61010-1 EN... |
General ELCB Testers
|
|
|
|
Sew 810 EL
|
FEATURES
● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.
SPECIFICATIONS
Wiring check LEDs
Line-Neutral = Green Line-Earth = Green Neutral-Earth =Red
Current settings
10-50mA@230Vac>
Current selection
Knob
Frequency of operation
50/60 Hz Sinusoidal
Over-Temperature Protection
Yes by NTC sensor Test stopped indication by Red Led.
Operating voltage (L-E)
230 Vac ±15%
Meter accuracy
±3% of full scale
Operating temperature
-5°C to 45°C
Storage temperature
-10°C to 55°C
Dimensions
150(L) × 73(W) × 50(D)mm
Weight
Approx. 220g
Safety standard
EN 61010-1 CAT III 265V EN 61326-1
|
Analogue ELCB Testers
|
|
|
|
Sew 1810 EL
|
FEATURES
● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).
SPECIFICATIONS
Current settings
10-50mA@230Vac>
Current selection
Knob
Frequency of operation
50/60 Hz Sinusoidal
Over-Temperature Protection
NO
Operating voltage (L-E)
230 Vac ±15%
Meter accuracy
±1% of full scale
Protection
Fused (200mA 250V)
Operating temperature
-5°C to 45°C
Storage temperature
-10°C to 55°C
Dimensions
170(L) × 165(W) × 92(D)mm
Weight
Approx. 730g
Safety standard
EN 50081-1 EN 50082-1
|
Analogue ELCB Testers
|
|
|
|
Sew 1811 EL
|
FEATURES
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
SPECIFICATIONS
Current settings
0-999mAac / 50Hz
Current selection
Knob
Phase start selection 0° and 180°
Referenced to Earth Yes
Over-temperature protection
Yes
Phase polarity trip Indicator
Referenced to Earth Yes
Operating voltage (L-E)
110 Vac to 450 Vac
Timer resolution
1ms (Max. Time = 99.999s)
Timer accuracy
1ms ±1ms
Current accuracy
±1% ±1mA
Current resolution
1mA
Voltmeter accuracy (50Hz)
50-350 Vac = ±2%±1V 350-450 Vac = ±5%±1V
Voltameter resolution
... |
Digital ELCB Testers
|
|