Sew 6200 IN (Ranges: 2.5kV, 5kV)
|
FEATURES
● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.
SPECIFICATIONS
Test voltage (DC V)
2500V
5000V
Measuring ranges
0-100GΩ
0-200GΩ
Accuracy
±5% of full scale
Live warning
>500V AC
Operating-temperature
0°C to 40°C
Operating-humidity
85% Max. relative humidity
Dimensions
330(L) × 260(W) × 160(D) mm
Weight (battery included)
Approx. 3500g
Power source
1.5V “C”× 8 Alkaline batteries
|
Analogue (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 6201 IN (Ranges: 5kV, 10kV)
|
FEATURES
● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.
SPECIFICATIONS
Test voltage (DC V)
5000V
10000V
Measuring ranges
0-200GΩ
0-400GΩ
Accuracy
±5% of full scale
Live warning
>500V AC
Operating-temperature
0°C to 40°C
Operating-humidity
85% Max. relative humidity
Dimensions
330(L) × 260(W) × 160(D) mm
Weight (battery included)
Approx. 3500g
Power source
1.5V “C”× 8 Alkaline batteries
|
Analogue (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 2803 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.
SPECIFICATIONS
Test voltage (DC V)
0.5kV / 1kV / 2.5kV / 5kV
Measuring ranges (Auto-Ranges)
0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
Accuracy
0-50GΩ : ±3% rdg 50-250GΩ : ±5% rdg
Dimensions
170(L) × 120(W) × 95(D)mm
Weight (battery included)
Approx. 930g
Power source
1.5V(AA) × 8
Safety standard
EN 61010-1 EN... |
Digital (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 2804 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.
SPECIFICATIONS
Test voltage (DC V)
1kV / 2.5kV / 5kV / 10kV
Measuring ranges (Auto-Ranges)
0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ
Accuracy
0-50GΩ : ±3% rdg 50-500GΩ : ±5% rdg
Dimensions
170(L) × 120(W) × 95(D)mm
Weight (battery included)
Approx. 1030g
Power source
1.5V(AA) × 8
Safety standard
EN 61010-1 EN... |
Digital (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.
SPECIFICATIONS
Test voltage (DC V)
0.5kV / 1kV / 2.5kV / 5kV
Measuring ranges (Auto-Ranges)
0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
Accuracy
±5% rdg
Output power limit
1W
Sealed with gasket
ˇ
Insulation resistance between electrical circuit and housing : 2000MΩ / 2000V
ˇ
Withstand voltage: 7000 Vac for one min. between electrical circuit and case
ˇ
Operation temperature
-15°C to 55°C
Operation-humidity
... |
Digital (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 4104 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.
SPECIFICATIONS
Test voltage (DC V)
1kV / 2.5kV / 5kV / 10kV
Measuring ranges (Auto-Ranges)
0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ
Accuracy
±5% rdg
Output power limit
1W
Sealed with gasket
ˇ
Insulation resistance between electrical circuit and housing : 2000MΩ / 2000V
ˇ
Withstand voltage: 7000 Vac for one min. between electrical circuit and case
... |
Digital (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 6210A IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.
SPECIFICATIONS
Test voltage (DC V)
0.5kV / 1kV / 2.5kV / 5kV
Measuring ranges (Auto-Ranges)
0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
Accuracy
±3% rdg
Output power limit
50uA to 100uA (1W)
Live warning
> 500V AC
Operation temperature
0°C to 40°C
Operation-humidity
85% Max. relative humidity
Dimensions
330(L) × 260(W) × 160(D)mm
Weight (battery included)
Approx. 3500g
Power source
1.5V “C”× 8 Alkaline batteries
Safety standard
EN 61010-1 EN 61326-1
|
Digital (1kV up) H.V. Insulation Testers
|
|
|
|
Sew 6211A IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
|
FEATURES
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.
SPECIFICATIONS
Test voltage (DC V)
1kV / 2.5kV / 5kV / 10kV
Measuring ranges (Auto-Ranges)
0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ
Accuracy
±3% rdg
Output power limit
50uA to 100uA (1W)
Live warning
> 500V AC
Operation temperature
0°C to 40°C
Operation-humidity
85% Max. relative humidity
Dimensions
330(L) × 260(W) × 160(D)mm
Weight (battery included)
Approx. 3600g
Power source
1.5V “C”× 8 Alkaline batteries
Safety standard
EN 61010-1 EN 61326-1
|
Digital (1kV up) H.V. Insulation Testers
|
|