|
|
BANTE Sulphide Ion Selective Electrode (US)
|
|
Ion Selective Electrodes
|
|
|
|
BANTE Reference Electrode
|
Reference electrodes are widely used for electrochemical measurements, combine mono pH electrode or mono ion selective electrode which can measures pH or ion concentration of liquid. |
Reference Electrode
|
|
|
|
BANTE WXG-4 Manual Polarimeter
|
WXG-4 manual polarimeter is ideal for determining concentration levels of samples for applications in the medical, pharmaceutical, educational and cosmetic industries etc.
Easy Measurement:
The polarimeter with 589 nm sodium lamp. Switch on the power, the polarized light beam will immediately radiate to the polarizer,
filter. You can observed distinct visual fields through eyepiece. |
Polarimeters
|
|
|
|
BANTE WXG-5 Semiautomatic Polarimeter
|
WXG-5 is a wide range semiautomatic polarimeter for measuring the concentration levels of samples, it widely used for cosmetic industries, medical, pharmaceutical and educational applications.
Easy Measurement:
The polarimeter with 589 nm sodium lamp. Switch on the power, the polarized light beam will immediately radiate to the polarizer,
filter. You can observed distinct visual fields through eyepiece. Put the sample cuvette into measuring field chamber, Press the
+ or - key, you will find an equal brightness. Note the measured value on screen, The measurement is completed. |
Polarimeters
|
|
|
|
BANTE WZZ-2A Automatic Polarimeter
|
WZZ-2A automatic polarimeter is a general-purpose polarimeter
with ±0.02 Degrees Optical Rotation accuracy. The instrument is applicable to food, university education, chemical and fragrance applications.
Features:
The instrument has an auto-control system, Switch on the power, the system will automatically search an optical zero point. Place
the sample tube into the measuring field chamber, the instrument will shows measured value immediately. |
Polarimeters
|
|
|
|
BANTE 900P Portable Multi-parameter Water Quality Meter
|
Bante900P multi-parameter meter is capable of measuring up to
9 water quality parameters, including pH, ORP, Ion, Conductivity
TDS, Salinity, Resistivity, Dissolved Oxygen, etc.
General Features:
Automatic Temperature Compensation (ATC) ensures highly
accurate measurements over the entire range.
Calibrationdue reminder helps you to calibrate meter regularly.
Automatic endpoint function freezes stable measured values.
Help message as a operational guide to helps you understand
how to use meter.
Setup menu lets user customize the calibration points, stability
conditions, date and time to meet measurement requirements.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP.
Stored data can be transferred into PC via USB communication
interface.
|
Multi-parameter Water Quality Meters
|
|
|
|
BANTE 901P Portable pH/Conductivity/°C/°F Meter
|
Bante 901P portable multi-parameter meter used for measuring
the pH, Conductivity and TDS of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|
Multi-parameter Water Quality Meters
|
|
|
|
BANTE 902P Portable pH/ORP/Conductivity/°C/°F Meter
|
Bante 902P portable multi-parameter meter used for measuring
the pH, ORP, Conductivity, TDS, Salinity and Resistivity of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
... |
Multi-parameter Water Quality Meters
|
|