Sew 1106 IM
|
FEATURES
● Large LCD : 68 × 34mm (2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.
SPECIFICATIONS
Measuring ranges
0-20Ω / 0-200Ω / 0-2kΩ
Test frequency
1kHz
Accuracy
20Ω:±2%rdg±2dgt or ±0.1Ω Which is greater 200Ω/2kΩ : ±2%rdg±2dgt
Low battery indication
“ “ Symbol appears on the display
Data hold indication
“ “ Symbol appears on the display
Dimensions
175(L) × 85(W) × 75(D)mm
Weight (battery included)
Approx. 600g
Power source
1.5V (AA) × 8
Safety standard
EN 61010-1 CAT III 200V EN 61326-1
|
Audio Impedance Testers
|
|
|
|
Sew ALS-2
|
FEATURES
● x10 Model allows for more accurate measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.
SPECIFICATIONS
Input plug
US / Europe
Output socket
3 prong U.S. standard
Cord length
10cm
Max. Voltage/Ampere rating
120Vac(±10%)/10Aac For ETL (UL 61010-1) 250Vac(±10%)/10A For CE (EN 61010-1)
Operating Temperature & Relative Humidity
0℃~50℃ Max.80%R.H.
Weight
Approx. 135g
Dimensions
145(L)x55(W)x35(H)mm
|
AC Line Separators
|
|
|
|
Sew ALS-1
|
FEATURES
● x10 Model allows for more accurate measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.
SPECIFICATIONS
Input/Output line connector
3 prong U.S. standard
Max. Voltage/Ampere rating
120Vac(±10%)/10Aac
Operating Temperature & Relative Humidity
0℃~50℃ Max.80%R.H.
Weight
Approx. 110g
Dimensions
145(L) x 55(W) x 35(D)mm
|
AC Line Separators
|
|
|
|
Sew 6470 BT
|
FEATURES
● 2000 counts.● DC Voltage measurement.● 4-wire resistance measurement.● Data hold function.● Low battery indication.● 9V DC power supply.● Measure battery types: Li-ion, Ni-Cd, Ni-MH● Simple operation.● Lead resistance and contact resistance eliminated.
SPECIFICATIONS
DC Voltage
Range
2V
20V
100V
Resolution
1mV
10mV
100mV
Accuracy
±(1%rdg+1dgt)
±(1%rdg+1dgt)
±(1%rdg+1dgt)
Resistance
Range
200mΩ
2000mΩ
20Ω
Resolution
0.1mΩ
1mΩ
10mΩ
Accuracy
±(3%rdg+3dgt)
±(3%rdg+3dgt)
±(3%rdg+3 dgt)
General
Low battery indication
" " sign appears on the display when the battery voltage drops below accurate operating level.
Dimensions
192(L) × 88.6(W) × 45.2(D)mm
Weight (battery included)
Approx. 360g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT I 100V EN... |
Battery Tester
|
|
|
|
Sew ITC 8
|
FEATURES
● The ITC 8 can be utilized to check calibration of resistance ranges of insulation testers and multimeters.● The resistance checker box is also used to verify insulation testers and multimeters.
SPECIFICATIONS
Resistance Ranges
0.5Ω, 1Ω, 2Ω, 20Ω, 200Ω, 1kΩ, 10kΩ, 20kΩ, 100kΩ, 1MΩ, 2MΩ, 10MΩ
Accuracy
0.5Ω - 2Ω : ± 0.05Ω 20Ω - 10MΩ : ±1%
Dimensions
150(L) x 72(W) x 60(D)mm
Weight
Approx. 180g
Safety Standard
EN 61010-1 CAT III 1000Vdc
|
Resistor Calibration Boxes
|
|
|
|
Sew RCB-3-1T(B)
|
FEATURES
● The RCB-3-1T is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
SPECIFICATIONS
Resistance ranges (Ω)
1M. 10M. 100M. 1G. 10G. 100G. 1T
Resistance tolerances
±1%(F)
Tolerance
± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ. ± 200ppm/°C : 10GΩ. 20GΩ. 50GΩ. 100GΩ. ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ
Max. working voltage
DC 10kV
Operating temperature
-30°C~75°C
Power coefficient
Below 3W
Connecting terminals
Binding Post : Resistance circuit and guard
Dimensions
430(L) × 324(W) × 127(D)mm
Weight
Approx. 4140g
|
Resistor Calibration Boxes
|
|
|
|
Sew RCB-3-1T(A)
|
FEATURES
● The RCB-3-1T is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
SPECIFICATIONS
Resistance ranges (Ω)
1M. 10M. 100M. 1G. 5G. 10G. 100G. 1T
Resistance tolerances
±1%(F)
Tolerance
± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ. ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ. ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ
Max. working voltage
DC 10kV
Operating temperature
-30°C~75°C
Power coefficient
Below 3W
Connecting terminals
Binding Post : Resistance circuit and guard
Dimensions
430(L) × 324(W) × 127(D)mm
Weight
Approx. 4140g
|
Resistor Calibration Boxes
|
|
|
|
Sew RCB-3
|
FEATURES
● The RCB-3 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
SPECIFICATIONS
Resistance ranges (Ω)
1M. 10M. 100M. 1G. 5G. 10G. 100G. 500G
Resistance tolerances
±1%(F)
Tolerance
± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ. ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ. ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ
Max. working voltage
DC 10kV
Operating temperature
-30°C~75°C
Power coefficient
Below 3W
Connecting terminals
Binding Post : Resistance circuit and guard
Dimensions
430(L) × 324(W) × 127(D)mm
Weight
Approx. 4140g
|
Resistor Calibration Boxes
|
|