Sew 1160 IN
|
FEATURES
● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm ( 2.677” × 1.338” ) large LCD display.● LCD backlight display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function.● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
250V / 500V / 1000V
Measuring ranges (Auto ranging)
0-20MΩ / 0-200MΩ / 0-2000MΩ
Output voltage open circuit
+10%
Accuracy
0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt)
Resolution
0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ
Output current
1mA DC
AC Voltage
Range
0-500V
Resolution
1V
Line frequency range
40-120 Hz
Accuracy
±(1.5%rdg+3dgt)
Current for continuity
Measuring range
0-200Ω
... |
Digital (1kV below) Insulation Testers
|
|
|
|
Sew 1651 IN
|
FEATURES
● Microprocessor-controlled.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
250V / 500V / 1000V
Measuring ranges (Auto ranging)
0-20.00MΩ 0-200.0MΩ 0-2000MΩ
Output voltage open circuit
Rated test voltage +10%
Accuracy
20MΩ : ±(1.5%rdg+2dgt) 200MΩ : ±(2.5%rdg+2dgt) 2000MΩ : ±(5%rdg+3dgt)
Resolution
0-20.00MΩ : 10kΩ 0-200.0MΩ : 100kΩ 0-2000MΩ : 1MΩ
Output current
1mA DC
AC Voltage
Range
0-500V
Resolution
1V
Accuracy
±(1.5%rdg+3dgt)
Continuity
Ranges
20Ω / 200Ω / 2000Ω
Resolution
0-20Ω : 0.01Ω... |
Digital (1kV below) Insulation Testers
|
|
|
|
Sew 1801 IN
|
FEATURES
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
SPECIFICATIONS
Insulation Resistance
Test voltage (DC V)
50V / 125V / 250V
Measuring ranges
0-20MΩ / 0-50MΩ / 0-100MΩ
Output voltage on open circuit
Rated test voltage +10%
Accuracy
±5% of indicated value
Short circuit terminal current
2mA DC
Power consumption
190mA
Continuity
Measuring range
0-50Ω & ∞
Accuracy
± 5% of scale length
Open circuit terminal voltage
445mV DC Approx.
Short circuit terminal current
145mA DC Approx.
Power consumption
200mA
AC Voltage
Range
0-600V AC
Accuracy
± 2.5% of full scale
Line frequency range
40-1kHz
General
Dimensions
170(L) × 165(W) × 92(D) mm
Weight ... |
Insulation Testers (For Telecoms)
|
|
|
|
Sew 1100 IN
|
FEATURES
● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test button.
SPECIFICATIONS
Insulation Resistance
Test voltage (DC V)
100V
Output voltage on open circuit
Rated test voltage +10%
Measuring ranges
0-200MΩ
Mid-scale value
5MΩ
Accuracy
0.2-100MΩ : ± 5% rdg 0.7% of scale length at other ranges
Short circuit current
1mA DC
AC Voltage
Range
0-500V
Accuracy
± 2.5% of full scale
General
Operating temperature & humidity
0°C ~ 40°C relative humidity up to 85%
Storage temperature & humidity
-10°C ~ 50°C relative humidity up to 85%
Dimensions
175(L) × 85(W) × 75(D) mm
Weight (battery included)
Approx. 510g
Power source
1.5V (AA) × 4
Safety standard
EN... |
Insulation Testers (For Telecoms)
|
|
|
|
Sew 6213A IN-M
|
FEATURES
● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off
SPECIFICATIONS
Test voltage
From 500Vdc to 10kVdc Adjustable in 500V Steps
Preset buttons
1kV, 2.5kV, 5kV, 10kV
Measuring range
800kΩ-500GΩ (auto-ranging)
Accuracy
±5% ± 2 digits
Output power limit
1W
Voltage regulation
Selected Voltage +20%-5% of nominal value unless current limited. Meaning that if output current is too high, the voltage will... |
H.V. Insulation Testers (OLED Display 1kV up)
|
|
|
|
Sew 4167 MF
|
FEATURES
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
SPECIFICATIONS
Earth Resistance
Measuring system
Earth resistance by constant current inverter 820Hz, 2mA approx.
Measuring Ranges
Earth resistance: 0-12/0-120/0-1200Ω Earth voltage: 0-30V AC 40-500Hz
Accuracy
Earth resistance: ±3% F.S. Earth voltage: ±2.5% F.S.
Insulation
Test voltage(DC V)
250V
500V
Measuring ranges
0-100MΩ
0-200MΩ
Output voltage on open circuit
Rated test voltage +10%
... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
Sew 4175 TMF
|
FEATURES
● Microprocessor-controlled.● Telecommunication test voltage : 50V and 100V.● Large range of insulation test voltages: 50, 100, 125, 250, 500, 1000V.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Battery test at Switch ON-TEST.● Smart hold & Stop on voltmeter AC/DC.● eads AUTO-NULL Key.● Test Auto-stop.● Auto range.● Ener-Save™.
SPECIFICATIONS
Insulation Resistance
Test voltage (DC) and Measuring ranges
50V / 0.1MΩ~400MΩ 100V / 0.1MΩ~800MΩ 125V / 0.1MΩ~1GΩ 250V / 0.2M~2GΩ 500V / 0.2MΩ~4GΩ 1000V / 0.2M~8GΩ
Output voltage @ 1mA
Rated test Voltage +10%
Accuracy
0.1MΩ~4GΩ : ±3%rdg 4MΩ~8GΩ : ±5%rdg
Nominal voltage rated
1mA
Short circuit current
1.2mA
Polarization index(PI)
ˇ
Detective absorption ratio (DAR)
ˇ
Continuity
Ranges
0.01~100Ω / 100 ~300Ω / 300~1999Ω
... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
Sew 4153 IN
|
FEATURES
● Microprocessor-controlled.● Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA.● Auto-off function.● Energy conservation feature.● Ener-Save™ limit the test duration to about 10 Seconds.● Quick Test and EnerSave™ are unique features. Both saves energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Operates with rechargeable batteries, alkaline or low cost general purpose batteries.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
SPECIFICATIONS
Insulation Test
Test voltage (DC V) and Measuring ranges
250V / 0.2M~2GΩ 500V / 0.2M-4GΩ 1000V / 0.2M-8GΩ
Output voltage @ 1mA
Rated test Voltage +10% Max
Accuracy
0.2M~4GΩ : ±3%rdg 4GΩ~8GΩ : ±5%rdg
When voltage is constant, Current is limited at
... |
Insulation & Multifunction Testers (LCD Display)
|
|