Sew 4105 ER
|
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac(40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820 Hz, 2mA approx.
Open circuit indication
LED will be unlit
Dimensions
250(L) × 190(W) × 110(D)mm
Weight (battery included)
Approx. 1500g
Power source
1.5V (AA) × 8
Safety standards
EN 61010-1 CAT III 30V EN 61326-1
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew 2705 ER
|
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820 Hz, 2mA approx
Open circuit indication
LED will be unlit
Dimensions
205(L) × 90(W) × 55(D)mm
Weight (battery included)
Approx. 514g
Power source
1.5V (AA) × 6
Safety standards
EN 61010-1 CAT III 30V EN 61326-1
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew 2105 ER
|
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820 Hz, 2mA approx.
Open circuit indication
LED will be unlit
Dimensions
210(L) × 210(W) × 100(D)mm
Weight (battery included)
Approx. 1370g
Power source
1.5V (AA) × 8
Safety standards
EN 61010-1 CAT III 30V EN 61326-1
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew 1805 ER
|
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820Hz, 2mA approx.
Open circuit indication
LED will be unlit
Dimensions
170(L) × 165(W) × 92(D)mm
Weight (battery included)
Approx. 1000g
Power source
1.5V (AA) × 8
Safety standards
EN 61010-1 CAT III 150V EN 61326-1
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew 1105 ER
|
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820 Hz, 2mA approx.
Open circuit indication
LED will be unlit
Dimensions
175(L) × 85(W) × 75(D)mm
Weight (battery included)
Approx. 600g
Power source
1.5V (AA) × 8
Safety standards
EN 61010-1 CAT IV 30V EN 61326-1
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew ST-1505
|
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to five minutes when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON” are pressed together. ● This will keep test “ON” for the duration of the timer.● Battery check function. ● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz)
Accuracy
Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale
Measuring system
Earth resistance by constant current inverter 820 Hz, 2mA approx.
Open circuit indication
LED will be unlit
Dimensions
163(L) × 100(W) × 50(D)mm
Weight (battery included)
Approx. 460g
Power source
1.5V (AA) × 6
Safety standards
IEC 1010 CAT II 30V
|
3 Wire (Analogue) Earth Resistance Testers
|
|
|
|
Sew 4120 ER
|
FEATURES
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz)
Accuracy
Earth resistance ±(2%rdg+2dgt) at 200/2000Ω ±(2%rdg+0.1Ω) at 20Ω Earth voltage ±(1%rdg+2dgt)
Earth resistance resolution
0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω
Measuring system
Earth Resistance by constant current inverter 820Hz approx. 2mA
Display
3½ digit (2000 counts)
Open circuit indication
LED will be unlit
Low battery indication
“ “symbol appears on the display
Data hold ... |
3 Wire (Digital) Earth Resistance Testers
|
|
|
|
Sew 2720 ER
|
FEATURES
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz)
Accuracy
Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt)
Earth resistance resolution
0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω
Measuring system
Earth Resistance by constant current inverter 820Hz approx. 2mA
Display
3½ digit (2000 counts)
Open circuit indication
LED will be unlit
Low battery indication
“ “symbol appears on the display
Data hold ... |
3 Wire (Digital) Earth Resistance Testers
|
|