Kyoritsu 2432
|
High Sensitive Model
•
Frequency Selector Switch to eliminate the effect of harmonics.
•
Three AC current ranges : 4mA/40mA/100A
|
Leakage Clamp Meters
|
|
|
|
Kyoritsu 2433
|
Frequency Selector Switch to eliminate the effect of harmonics.
•
Three AC current ranges : 40mA/400mA/400A.
|
Leakage Clamp Meters
|
|
|
|
Kyoritsu 2433R
|
Frequency Selector Switch to eliminate the effect of harmonics.
•
Three AC current ranges: 40mA/400mA/400A.
|
Leakage Clamp Meters
|
|
|
|
Kyoritsu 2434
|
Least affected by external stray magnetic field.
•
20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
•
Frequency Selector Switch to eliminate the effect of harmonics.
|
Leakage Clamp Meters
|
|
|
|
Kyoritsu 5010 (for Current) / 5020 (for Current & Voltage)
|
3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
•
Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)
Large Capacity for storing 60,000 data points
60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
Lowpass Filter will filter out the harmonics(Cutoff Frequency = Approx. 160Hz)
LED flickers when the preset current / voltage value is exceeded
CALL: Confirmation of recorded data
•
The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
•
RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
|
Logger
|
|
|
|
Kyoritsu 5001
|
THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED
60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
Continuous measurement time
About 40 days
Data where it doesn’t disappear even if battery is consumed
Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)
Battery residual display
The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)
The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software
|
Logger
|
|
|
|
Kyoritsu 8309
|
Floating voltage can be measured
*Floating voltage:phase to phase voltage not grounded
*KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.)
For use with following model
5020
|
Voltage Sensor
|
|
|
|
Kyoritsu 8130
|
Can measure AC current up to 1000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|