|
|
Fluke i5sPQ3 AC 5A Current Clamp (3 Pack)
|
Low level current clamp measures up to 5 A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
|
Current Clamp DMM Accys
|
|
|
|
Fluke i6000s Flex-24 AC Current Clamp (24in.)
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1% of range (45–65 Hz)
Linearity (10% to 100% of range): ±0.2% of reading
|
Current Clamp DMM Accys
|
|
|
|
Fluke i6000s Flex-36 AC Current Clamp (36in.)
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1% of range (45–65 Hz)
Linearity (10% to 100% of range): ±0.2% of reading
|
Current Clamp DMM Accys
|
|
|
|
Fluke i800 AC Current Clamp Probe
|
Measures AC current from 100mA to 800 A rms
30 Hz to 10 kHz frequency range
CAT III 600 V rating
Accepts up to 54 mm (2.1 in) diameter conductor size
1000:1 conversion factor for easy calculation
Rugged positive action design
|
Current Clamp DMM Accys
|
|
|
|
Fluke 140S-PR Clamp-on Current Transformer
|
Operates with the Fluke 1750 Power Recorder
It supplies accurate nonintrusive measurement of ac current
The probe has a current range from 0.05 A to 40 A
The frequency range is 40 Hz to 5 kHz
The clamp is approved for CAT III 600 V
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3100R Clamp-on Current Transformer
|
Current range: 1-1000A
Accuracy: 1% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 2" dia. (5 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3112RPM Flexi-CT™ Flexible Current Transformer
|
Current range: 2-100
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 7 kHz
Length: 48” (1.2 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3120R Clamp-on Current Transformer
|
Current range: 0.05-200A
Accuracy: 1% RDG +/- 0.3% FS
Frequency response: 5 kHz
Jaw opening: .78” dia. (2 cm)
|
Current Clamp DMM Accys
|
|