Sew ST-3502
|
FEATURES
● 3½ digit, high contrast LCD, with a maximum display of 1999.● Automatic polarity indication, zero adjust.● Low battery (BAT) indication.● Over range indication: highest digit of (1) or (-1).
ANALOG DISPLAY
● Large 90º wide and 84mm long mirror scale. (adapted to digital, analog maximum indication 2400).● Peak hold mode.● Shock and vibration resistant TAUT BAND movement.● Switch selection normal (left hand side) zero or center (galvo-mode) zero. Polarity + or -, pointer turn to right hand side, avoid opposite direction.● Centre zero and ohm zero : automatic● Dimensions: 167(L) × 102(W) × 39(D)mm
SPECIFICATIONS
DC... |
Analogue+Digital Multimeter
|
|
|
|
Sew 4137 mO
|
FEATURES
● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
SPECIFICATIONS
Measuring ranges
0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω
Accuracy
±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads
Test current
1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges
Test current accuracy
±0.1%
Protection fuses
Mains = 0.5A,... |
Milliohm Meters
|
|
|
|
Sew 4136 mO
|
FEATURES
● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
SPECIFICATIONS
Measuring ranges
0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω
Accuracy
±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads
Test current
1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges
Test current accuracy
±0.1%
Protection fuses
Mains = 0.5A,... |
Milliohm Meters
|
|
|
|
Sew 6237 DLRO
|
FEATURES
● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over- voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
SPECIFICATIONS
Low resistance ranges / resolution
0-2.000mΩ / 1μΩ 0-20.00mΩ / 10μΩ 0-200.0mΩ / 100μΩ 0-2.000Ω / 1mΩ 0-20.00Ω / 10mΩ 0-200.0Ω / 100mΩ
Accuracy
0-2.000mΩ : ±(5%rdg+5dgt) 0-20.00mΩ : ±(4%rdg+4dgt) 0-200.0mΩ : ±(4%rdg+4dgt) 0-2.000Ω : ±(3%rdg+4dgt) 0-20.00Ω : ±(2%rdg+4dgt) 0-200.0Ω : ±(2%rdg+4dgt)
Test current (dc)
2.000mΩ to 200.0mΩ :... |
Low Resistance Ohm Meter
|
|
|
|
Sew 1807 TB
|
FEATURES
● AC Voltage Input/output range: 100~240 Vac● Frequency: 50~60Hz● Current: 10A
SPECIFICATIONS
Current capacity
10Aac(125V)
Withstand voltage
2210Vac for 1 minute between the electric circuit and the case
ACV Input/Output
100~240V 50/60Hz
Dimensions
170(L) x 165(W) x 92(D)mm
Weight
Approx. 820g
Meets
EN 61010-1 CAT.Ⅲ 250V
|
AC & DC Analog Leakage Meters
|
|
|
|
Sew 2108 EL
|
FEATURES
● High quality Taut Band movement.● Four functions : DC current, AC current, AC+DC current, and ACV measurement.● Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.● 200uA full scale value.● ±2.5% full scale value accuracy.● Built-in overload protection circuit.● Robust, compact and easy to carry.
SPECIFICATIONS
Ranges
DC Current : 0.1-1-10mA AC Current : 0.1-1-10mA AC+DC current : 0.1-1-10mA AC Voltage : 150-300V (50/60Hz) Accuracy : ±2.5% of full scale
Input impedance
Current Ranges : 1kΩ, 1.5kΩ and 2kΩ Voltage Ranges : 150V/500kΩ 300V/1MΩ
Working frequency
20Hz ~5kHz
Overload protection
Withstands 30mA AC for 10 minutes for each current measuring range
Operating temperature
0ºC ~ 40ºC
Operating humidity
Max. 80% R.H.
Dimensions
210(L) × 210(W) × 100(D)mm
Weight (battery included)
Approx. 1395g
Power source
1.5V (AA) × 8
Safety standard
EN 61010-1 CAT III 600V EN 61326-1
|
AC & DC Analog Leakage Meters
|
|
|
|
Sew 507 EL
|
FEATURES
● High quality movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.
SPECIFICATIONS
AC Leakage Current
Measuring range
0.3mA-1mA-3mA-10mA-30mA
Accuracy
±2% of full scale
Input resistance
1.5kΩ / 2kΩ
AC Voltage
Measuring range
0-150 / 0-300V
Accuracy
±2% of full scale
Input resistance
150V 500kΩ 300V 1MΩ
General
Low battery indication
Battery check indicate good battery from 7Vdc to 9Vdc during a load test of 2mA
Dimensions
160(L) × 100(W) × 45(D)mm
Weight (battery included)
Approx. 370g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN 61326-1
|
AC & DC Analog Leakage Meters
|
|
|
|
Sew 506 EL
|
FEATURES
● High quality movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.
SPECIFICATIONS
AC Leakage Current
Measuring range
0.3mA-1mA-3mA-10mA-30mA
Accuracy
±2% of full scale
Input resistance
1.5kΩ
AC Voltage
Measuring range
0-300 / 0-600V
Accuracy
±2% of full scale
Input resistance
300V 1MΩ 600V 2MΩ
General
Low battery indication
Battery check indicate good battery from 7Vdc to 9Vdc during a load test of 2mA
Dimensions
160(L) × 100(W) × 45(D)mm
Weight (battery included)
Approx. 360g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN 61326-1
|