Environmental/Process analyzers
| |
Name |
Description |
Category |
|
|
|
DKK-TOA OF-1600
|
Oil film is detected by measuring differences of the amount of LED reflectance of oil and water
Small and lightweight design
Contact-free and easy maintenance
Detectable range
About 0.5 m
|
Oil Film Detector
|
|
|
|
DKK-TOA SODL-1600
|
Oil Film Detector (Explosion-Proof Model) SODL-1600
Robust aluminum pressure resistance explosion-proof model
Oil film is detected by measuring differences of the amount of laser reflectance of oil and water
With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively
Contact-free and easy maintenance
Detectable range
0.3 - 3 m
|
Oil Film Detector
|
|
|
|
DKK-TOA FPM-377
|
PM2.5 Monitor FPM-377
Environment Ministry (JAPAN) Approval
Beta ray attenuation method (mass concentration)
Heater type dehumidifier
VSC cyclone (USEPA approval)
Outdoor type and indoor type available
Meas. range
0 - 500, 0 - 1000, 0 - 5000 μg/m3
|
Particulate Monitor
|
|
|
|
DKK-TOA FPM-222
|
US EPA Approval
Beta ray attenuation method (mass concentration)
Small and semi-permanent semiconductor detector is used to detect the Beta ray
Easy calibration with the calibration film
Meas. range
0 - 1000, 0 - 5000 μg/m3 (0 - 1, 0 - 5 mg/m3)
|
Particulate Monitor
|
|
|
|
DKK-TOA GLN-314E
|
Nitrogen Oxides Analyzer GLN-314E
US EPA Approval
Chemical luminescence method
Alternating measurement of nitric monoxide (NO) and nitrogen oxides (NOx) ensures stable and continuous measurement of minute amounts of nitrogen oxides in the air
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0, 0 - 2.0 ppm
|
Nitrogen Oxides Analyzer
|
|
|
|
DKK-TOA GFS-312E
|
Sulfur Dioxide Analyzer GFS-312E
US EPA Approval
Continuous measurement of SO2 by using Ultraviolet fluorescence method
Improved optical system reduces the impact from interfering substances
Easy-to-use touch panel
Meas. range
0 - 0.05, 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Sulfur Dioxide Analyzer
|
|
|
|
DKK-TOA GUX-313E
|
Ozone Analyzer GUX-313E
US EPA Approval
Continuous measurement of O3 concentration by using UV photometry method
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Ozone Analyzer
|
|
|
|
DKK-TOA GFC-311E
|
Carbon Monoxide Analyzer GFC-311E
US EPA Approval
Gas filter correlation method (IR method)
High sensitivity measurement enabled with multi-reflection cell
Easy-to-use touch panel
Meas. range
0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm
|
Carbon Monoxide Analyzer
|
|