|
|
Testo 425-KIT (400563 4251) Thermal Anemometer Kit, Temperature, Flow and Volume Flow
|
Temperature, flow and volume flow measurement
Multi-point and timed mean calculation
Max/min values
Hold button to freeze readings
Display light
Auto Off function
Includes a soft carrying case
TopSafe case protects against dirt and impact (optional)
|
Anemometers
|
|
|
|
Testo 445 (0560 4450) VAC Testing Anemometer
|
Automatic mean calculation and volume flow measurement
Automatic allocation of duct cross-section to location (max. 99 locations)
Internal data logger (3,000 readings)
Simultaneous measurement of up to 6 parameters
|
Anemometers
|
|
|
|
Testo 6445-1 (0699 6445 1) Compressed Air Flowmeter
|
Measuring range: 0 to 80 Nm/sec
Robust, thermal silicon chip sensor
Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12")
Includes 5-point calibration certificate
Minimum flow required: 1 m/sec
Ambient temperature: -10 to +60° C
Accuracy: +/-3 percent of reading, /-0.4 percent of final value
Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin
Response time: t90 approximately 5 seconds
Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)
|
Anemometers
|
|
|
|
Testo 6445-2 (0699 6445 2) Compressed Air Flowmeter
|
Measuring range: 0 to 150 m/sec
Robust, thermal silicon chip sensor
Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12")
Includes 5-point calibration certificate
Measuring range: -50 to 400 ° C
Minimum flow required: 2 m/sec
Accuracy: +/-3 percent of reading, /-0.4 percent of final value
Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin
Response time: t90 approximately 5 seconds
Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)
|
Anemometers
|
|
|
|
Testo 315-2 (0632 0317) CO Tester
|
Reliable warning of CO poisoning
DVGW approval
Adjustment of different alarm limits
Printout with date/time and recommended value (alarm limit)
With calibration protocol
TopSafe, protection case for tough applications
Quick and practical documentation of data on location, printout with date/time and recommended value (alarm limit)
|
CO Meters
|
|
|
|
Testo 317-3 (0632 3173) CO Monitor for carbon monoxide detection
|
3 year warranty on CO cell
Visual and audible alarm
No zeroing required, just turn it onto measure
Adjustable alarm threshold
Self-test mode verifies CO sensor function anytime, anywhere without the need for test gas
|
CO Meters
|
|
|
|
Testo 310 Combustion Analyzers
|
The Testo 310 can stand up to the toughest job site
Five-line backlit display with two-line readout and easy-to-navigate menu
30 second start-up time
Work all day with a 10-hour rechargable battery
Quick swapable replacement filters
Powerful magnets in the 310 allows for hands-free operation
Easy emptying of the integrated condensate trap
Wireless printer option with integrated magnets
|
Combustion Analyzers
|
|
|
|
Testo 320 Combustion Analyzers
|
High-definition & easy to understand graphic display
Simple "Traffic Light" sensor diagnostics & monitoring
30 second start-up time
Ultra-rugged & hard rubberized housing to withstand work-place abuse
Work all day with Lithium rechargable battery technology
Internally housed magnets for hands-free operation
Easy to see & replace probe filters
Hardened cam-lock fittings that are leak-free
Replacable sensors that last up to 3 years
Stores up to 500 tests with on-site printing and download options
|
Combustion Analyzers
|
|